AQUAMASTER

The AQUAMASTER Conventional Water Leakage Detection Panel range offers a creatively designed and visually pleasing solution for smaller cost-conscious projects demanding simplicity of operation. Versions available include 2, 4 and 8 zone panels and two styles of repeater. It monitors up to 8 Signaline WDM-KM Control Modules each of which controls up to 1000m of Signaline WD Water Detection Cable.

The outstanding programmable features included in this panel range contradict the facilities commonly available in this type of panel and include: programmable time delay by zone, Day/Night mode, selectable non-latching zones and coincidence detection.

Operation is extremely intuitive, offering simple control and one-button disablement facilities, as well as the one man test mode which provides simple and efficient testing of the system.

Advanced configuration solutions include the following: a dedicated RS232 communication interface allowing connection of up to 4 remote repeater panels, addressable loop interface modules and multiplexed zonal output relays; giving one of the most highly advanced levels of system integration and compatibility existing on the market at
this level.

TECHNICAL SPECIFICATIONS

PRIMARY SUPPLY VOLTAGE- IN 230 +10% -15% V AC
PRIMARY SUPPLY VOLTAGE- OUT 28.5V DC nominal
PRIMARY SUPPLY CURRENT-OUT 1.7A @ 28.5V DC nominal (max.)
SECONDARY SUPPLY VOLTAGE 21.0 min. – 27.2 max. V DC – BAT charger o/p 28 V DC
SECONDARY SUPPLY CURRENT OUTPUT 1.1 Amp Maximum @ 200C
INTERNAL BATTERY CAPACITY – MAXIMUM 2 x 12V x 7Ah Sealed VRLA Lead Acid Batteries
MAINS FUSE 4 A -250 V Slow Blow – 20 mm
BATTERY FUSE 1.6 Amp – Resettable
DETECTION CIRCUIT SPECIFICATION
NUMBER OF CIRCUITS 2,4 or 8
ZONE CURRENT – QUIESCENT / ALARM 4 mA / 60 mA – Maximum
MAX. CABLE RESISTANCE / CAPACITANCE 40 Ohms / 0.470 uF
END OF LINE MONITORING Active EOL – Capacitor
Bs5839 DETECTOR REMOVAL COMPLIANT YES provided diodes are fitted to detector base
DEVICES PER ZONE 1 WDM-KM Control Module – controls up to 1000 m of Signaline WD Water Detection Cable
ALARM RESISTANCE VALUE 270 – 1000 Ohms
SOUNDER CIRCUIT SPECIFICATION 2 – 500mA max. current drive per circuit – fully monitored
ALARM VOLTAGE / END OF LINE RESISTOR 27.5 V DC Nominal / 10 K Ohms – 1/4 Watt
AUXILIARY OUTPUTS SPECIFICATION
AUXILIARY RELAY OUTPUT 1 Fire (COM-NC-NO) – 1 Fault (COM-NC) non-supervised
RELAY CONTACT RATING 50 V DC – 1 Amp resistive loads
REMOTE INPUT SPECIFICATION
EVACUATION (CC) – DAY/ NIGHT MODE Non-Latching – Voltage free contact
RESET Non-Latching – Voltage free contact
MECHANICAL & OPERATING SPEC.
MAX. HUMIDITY 95% RH Non-Condensing
OPERATING TEMPERATURE -10ºC to 50ºC
WEIGHT 1.7 Kg – 7 Kg (inc. 2 x 7 AH 12 V bat.)
DIMENSIONS 272 (W) x 404 (H) x 107 (D) mm
COLOUR White or Red